Gas-dynamic spraying of hydroxyapatite on medical instruments from titanium alloy

D. A. Pervushin, I. V. Shishkovsky, I. Yu Smurov

Research output: Contribution to journalArticlepeer-review

2 Citations (Scopus)

Abstract

The applicability of hydroxyapatite powder for the D-gun spraying of medical instruments made of titanium alloys is investigated. Previously determined parameters of spraying are refined in order to attain good adhesion binding of the coating with the substrate. The multizone character of sprayed microstructures is shown by the results of optical and electron scanning microscopy with energy dispersive microanalysis. It is established that hydroxyapatite is not subjected to substantial variations after spraying, which is important for medical applications.

Original languageEnglish
Pages (from-to)298-302
Number of pages5
JournalRussian Journal of Non-Ferrous Metals
Volume55
Issue number3
DOIs
Publication statusPublished - Jul 2014
Externally publishedYes

Keywords

  • cool spraying and D-gun spraying
  • hydroxyapatite ceramics
  • medical instruments
  • nitinol
  • titanium alloys

Fingerprint

Dive into the research topics of 'Gas-dynamic spraying of hydroxyapatite on medical instruments from titanium alloy'. Together they form a unique fingerprint.